5700A/5720A Series II
Operators Manual
3-14
Table 3-2. Rear Panel Features (continued)
I
Line Voltage Switch and Fuse
Rating Label
Shows the various settings of the line voltage switches, and the correct
replacement fuse ratings for fuse F1 for operating voltages of 110 (90-132)
and 220 (180-264) V ac. Refer to "Accessing the Fuse" in Chapter 2 for the
fuse replacement procedure.
J
F1 Fuseholder
The line power fuse. Refer to "Accessing the Fuse" in Chapter 2 for fuse
rating information and the fuse replacement procedure.
K
AC PWR INPUT Connector
A grounded male three-prong connector that accepts the line power cord.
L
Line Voltage Selection
Switches
Select the operating line voltage. Refer to "Selecting Line Voltage" in
Chapter 2 for how to select operating line voltage.
M
CHASSIS GROUND Binding
Post
A binding post that is internally grounded to the chassis. If the calibrator is
the location of the ground reference point in a system, this binding post can
be used for connecting other instruments to earth ground. (The chassis is
normally connected to earth ground through the three-conductor line cord
instead of through the earth ground binding post.) Refer to "Connecting to
the UUT" in Chapter 4 for details.
10111213
VOLTAGE
SELECTION
FUSE-F1
T 3A
250V
(SB)
100V
S2 S3 S4
110V
115V
120V
VOLTAGE
SELECTION
FUSE-F1
T 1.5A
250V
(SB)
200V
S2 S3 S4
220V
230V
240V
9
Figure 3-2. Front Panel Features (continued)
3-5. Softkey Menu Tree
The functions of the six softkeys described under “Front Panel Features”, are represented
by menus containing labels displayed directly above each key. These functions change
whenever you access a new menu. Figure 3-3 shows the hierarchy of all the menus
available for the calibrator.

Table of Contents

Other manuals for Fluke 5700A Series II

Related product manuals