Fluke 5700A Series II User Manual

Fluke 5700A Series II
336 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #87 background imageLoading...
Page #87 background image
4-1
Chapter 4
Front Panel Operation
Title Page
4-1. Introduction........................................................................................... 4-3
4-2. Powering on the Calibrator................................................................... 4-4
4-3. Warm Up............................................................................................... 4-4
4-4. DC Zeros............................................................................................... 4-5
4-5. Executing DC Zeros ......................................................................... 4-5
4-6. DC Zeros Reminder.......................................................................... 4-5
4-7. The Setup Menu.................................................................................... 4-6
4-8. Instrument Setup............................................................................... 4-7
4-9. Format EEPROM Menu................................................................... 4-7
4-10. Spec Format Setup Menu ................................................................. 4-8
4-11. Setting the Internal Clock/Calendar ................................................. 4-9
4-12. Selecting Amplifiers......................................................................... 4-10
4-13. Checking the Instrument Configuration ........................................... 4-11
4-14. Special Functions Menu. .................................................................. 4-12
4-15. Resetting the Calibrator. ....................................................................... 4-12
4-16. Operate and Standby Modes ................................................................. 4-13
4-17. Connecting the Calibrator to a UUT..................................................... 4-13
4-18. Recommended Cable and Connector Types..................................... 4-13
4-19. When to Use External Sensing ......................................................... 4-14
4-20. When to Use the External Voltage Guard ........................................ 4-15
4-21. When to Use the Current Guard ....................................................... 4-15
4-22. Four-Wire Vs. Two-Wire Resistance Connections .......................... 4-16
4-23. Cable Connection Instructions ......................................................... 4-16
4-24. Setting the Output ................................................................................. 4-22
4-25. DC Voltage Output........................................................................... 4-24
4-26. AC Voltage Output........................................................................... 4-25
4-27. DC Current Output ........................................................................... 4-27
4-28. AC Current Output ........................................................................... 4-28
4-29. Resistance Output............................................................................. 4-30

Table of Contents

Other manuals for Fluke 5700A Series II

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fluke 5700A Series II and is the answer not in the manual?

Fluke 5700A Series II Specifications

General IconGeneral
TypeMultifunction Calibrator
Operating Temperature0 °C to 50 °C
Storage Temperature-20 °C to 70 °C
Voltage Range0 to 1100 V
DC Voltage Range10 μV to 1100 V
Frequency Range1 MHz
Humiditynon-condensing
Power Requirements100 V to 240 V