A traceable calibration procedure for all modes and ranges that requires only 10 V,
1 , and 10 k external standards, with only occasional independent verification
Fast, simple, automated calibration check providing added confidence between
calibration recalls, and data that can be used to document and characterize the
calibrator’s performance between calibration recalls
1-2. Instruction Manuals
The 5700A/5720A Series II Calibrators ship with a complete manual set that contains
information for the operator and service or maintenance technicians. The set includes:
5700A/5720A Series II Getting Started Manual (PN 1668111)
5700A/5720A Series II Operator Reference Guide (PN 601648)
5700A/5720A Series II Remote Programming Reference Guide (PN 601655)
5700A/5720A Series II Operator Manual (provided on CD-ROM, PN 1668127, or a
printed copy is available for purchase through the Fluke Service Department under
PN 601622)
5700A/5720A Series II Service Manual (provided on CD-ROM, PN 1668127, or a
printed copy is available for purchase through the Fluke Service Department under
PN 105798)
Order additional copies of these instruction manuals separately using the part numbers
provided. For ordering instructions, refer to the Fluke Catalog or contact a Fluke sales
representative.
1-3. About this Manual
This manual provides complete information for installing the calibrator and operating it
from the front panel keys and in remote. It also provides a glossary of calibration-related
terms as well as general items such as specifications and error code information. The
following topics are covered in this manual:
Installation
Operating controls and features
Front panel operation
Remote operation (IEEE-488 bus or serial port remote control)
Serial port operation (printing, displaying, or transferring data, and setting up for
serial port remote control)
Operator maintenance, including how to calibrate the 5700A/5720A Series II
Calibrator
Options and accessories

Table of Contents

Other manuals for Fluke 5700A Series II

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fluke 5700A Series II and is the answer not in the manual?

Fluke 5700A Series II Specifications

General IconGeneral
TypeMultifunction Calibrator
Operating Temperature0 °C to 50 °C
Storage Temperature-20 °C to 70 °C
Voltage Range0 to 1100 V
DC Voltage Range10 μV to 1100 V
Frequency Range1 MHz
Humiditynon-condensing
Power Requirements100 V to 240 V