Versiv Series Cabling Certification Product Family
Technical Reference Handbook
108
GPU68.EPS
Figure 42. Twisted Pair Length Results
Note
You can also measure length continuously. See
“Continuous Tests” on page 111.
PROPAGATION DELAY: The time taken for a test pulse to get
to the end of a wire pair.
DELAY SKEW: The differences in propagation delays between
the shortest delay and the delays of the other wire pairs. The
shortest delay shows as “0” in the delay skew results.
The tester shows a limit for propagation delay and delay skew
if the measurements are required by the selected test limit.
For measurements not required, the limit shows as N/A.