Chapter 11: The OptiFiber Pro OTDR Module
OTDR Port Connection Quality
333
on page 381 and 157 on page 387. If the tester shows a message
about the connection quality of the OTDR port, but the OTDR
connection on the tester is good, inspect the ends of the loopback
cord.
“STOP” Button for Manual Tests
When a trace shows on the PROGRESS screen for a manual OTDR
test with multiple wavelengths, you can tap the STOP button to
stop the OTDR test at the current wavelength and start the test at
the next wavelength. This lets you control the time the tester
takes to give OTDR results. You can stop the test to get results
more quickly, but the results are possibly less accurate.
GPU17.EPS
Figure 137. The OTDR Port Connection Quality Gauge
and Progress Screen
*
* Shows during Manual OTDR tests.