Chapter 5: Certify Coaxial Cabling
Coaxial Autotest Results
175
Resistance
The resistance measurement is the DC loop resistance of the
center conductor and the shield. The remote puts a short
between the conductor and the shield to make the loop.
Most coaxial standards do not have a limit for resistance. The
tester shows an when there is no limit.
Note
The resistance test on the TOOLS > Single Tests
menu lets you measure resistance continuously. This
function can help you locate intermittent faults.
Figure 80 shows the results from a resistance test.
GPU186.PNG
Figure 80. Coaxial Resistance Results