How to Add a Result to a Saved Result
507
How to Add a Result to a Saved Result
You can save the results from different tests in one cable ID. For
example, you can save CertiFiber Pro results and FiberInspector
results together in one ID.
When you add results, these settings used to get the results must
agree with the settings in the saved result:
Test limit
Fiber categories (singlemode/multimode, core size, category)
Index of refraction (makes a warning you can override)
If the settings do not agree, the tester shows a warning.
To add results for a different End setting
1 Do the test, then tap SAVE.
2 On the SAVE RESULT screen, select End 1 or End 2, make sure
the Cable ID and End name are correct, then tap SAVE.
To add results from a different test
1 On the home screen, tap the test setup panel.
2 On the CHANGE TEST screen, tap a test, then tap USE
SELECTED.
If the ID set has a Last ID, the home screen shows the first
ID in the set that does not have results for the test you
selected.
If the ID set does not have a Last ID, tap the Next ID panel,
tap the Next ID box on the CHANGE ID screen, enter the
first ID for the set of saved results, then on the CHANGE ID
screen, tap DONE.
3 Tap TEST or press , then save the result.