Versiv Series Cabling Certification Product Family
Technical Reference Handbook
278
If you are connected to fibers at a patch panel that are
connected together at the far end, and you are not sure
you are connected to the correct fibers, connect the
main tester’s INPUT fiber to different connections until
the test continues.
3-5 If Bi-directional is On: Halfway through the test, the tester
tells you to switch the input and output fibers. See “Bi-
directional Tests” on page 290.
3-6 If Auto Save is on, the tester uses the next ID to save the
results.
If Auto Save is off, the SAVE RESULT screen shows the next
ID available. You can change the ID if necessary.
Autotest Results for Loopback Mode
Figure 118 shows an example of Autotest results for Loopback
mode.
The overall result for the Autotest.
The loss and length measurements for the fiber:
The result exceeds the limit.
The result is within the limit.
The selected test limit does not have a limit for the test.
To see the results, limits, and margins for the fiber, tap the
window.
The settings the tester used for the test.
The dashed lines are around the connectors and fiber that are
included in the loss and length results. Gray connectors and
fibers are not included because you used them to set the
reference.