Versiv Series Cabling Certification Product Family
Technical Reference Handbook
482
PASS/FAIL Result for Edited Events
When you change a loss event’s type, the tester changes the loss
limit for the event and recalculates the event’s results and the
overall results. The recalculations can possibly change the PASS/
FAIL results. For example (refer to Figure 188):
You test a link and see a Loss event that has a loss of 0.53 dB.
This causes a FAIL result because the limit for a loss event is
0.30 dB.
You change the event to an APC Connector. Because the
selected test limit has a loss limit of 0.75 dB for connectors,
the result for the event changes to a PASS
If the loss event was the only FAIL result on the link, the
overall result will also change from FAIL to PASS.
Other Options for Editing Events
Use LinkWare PC to make these edits to events:
Change an event to a splice, APC connector, or splitter.
Add a 0 dB event to a trace where a splice or APC connector is
present but has very low loss and does not show in the event
table.
Add a note to any event.
Delete an event that has a loss of 0.35 dB or less. You can do
this to remove small loss events that are not caused by a splice
or APC connector. This makes the results show only the actual
components in a link.
To edit events in LinkWare PC
Use the buttons on the Events tab in the full-sized OTDR Trace
Viewer window. See the LinkWare PC online help for details.