EasyManua.ls Logo

Fluke Versiv Series - Step 3: Turn off the Auto Save Function; Step 4: Do an Autotest; Step 5: Look at the Results

Fluke Versiv Series
700 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Versiv Series Cabling Certification Product Family
Technical Reference Handbook
40
If the correct outlet configuration does not show, tap Outlet
Configuration. On the OUTLET CONFIG screen, tap the
correct configuration, then tap USE SELECTED.
AC Wire Map: This setting lets you do tests on links
connected through midspan PoE (Power over Ethernet)
devices. For this tutorial, make sure this setting is Off.
2-5 On the TEST SETUP screen, tap SAVE.
2-6 On the CHANGE TEST screen, tap the twisted pair test you
made, then tap USE SELECTED.
For more information on settings, see “Settings for Twisted Pair
Tests” on page 84.
Step 3: Turn Off the Auto Save Function
For this tutorial, you will manually save the test results.
3-1 On the home screen, tap the Next ID panel.
3-2 On the CHANGE ID screen, tap the Auto Save control to make
it show Off.
3-3 Tap DONE.
Step 4: Do an Autotest
4-1 Attach the channel adapters to the main and remote testers.
4-2 Turn on both testers, then connect a twisted pair cable
between the adapters.
4-3 Tap TEST on the main tester or press on the main or
remote tester.
Step 5: Look at the Results
The tester shows the Autotest results in three formats (Figure 11):

Table of Contents

Other manuals for Fluke Versiv Series