Chapter 17: Use Projects
About LinkWare Live
555
Note
The tester reads only USB drives that use the FAT
format.
1 Connect a USB flash drive to the type A USB port. The tester
makes a bell sound when it detects the drive.
2 On the home screen, tap the PROJECT panel.
3 On the PROJECT screen, tap TRANSFER.
4 On the TRANSFER PROJECTS screen, select a function:
Export: On the EXPORT PROJECTS screen, select the
projects you want to export to the flash drive, then tap
EXPORT.
Import: On the IMPORT PROJECTS screen select the
projects you want to import from the flash drive, then tap
IMPORT.
Delete: On the DELETE PROJECTS screen select the
projects you want to delete on the flash drive, then tap
DELETE.
Copy Project Settings to Other Testers
To copy the settings in a project to other testers, use the Read
Project Setups and Write Project Setups utilities in LinkWare PC
software. You can use LinkWare PC to read project settings from
a tester or from a project you exported to a flash drive.
About LinkWare Live
The LinkWare Live web application lets you manage your results
and projects from a desktop or mobile device. To get started with
LinkWare Live, see Chapter 18 or go to www.linkwarelive.com/
signin.