Versiv Series Cabling Certification Product Family
Technical Reference Handbook
326
GPU23.EPS
Figure 134. SET LAUNCH COMP Screen
The distance to the event.
The type of event. The tester looks for Launch and Tail events
approximately 100 m to 1 km from the fiber ends for
multimode fiber, and approximately 130 m to 3 km from the
fiber ends for singlemode fiber.
Select one event in the Launch column and one event in the
Tail column to be the launch and tail events.
: When the tester finds other events, it shows gray buttons
for events that you cannot select as a launch or tail event. For