Chapter 11: The OptiFiber Pro OTDR Module
Bi-directional SmartLoop Tests
389
The tester does not calculate averaged results in some
situations, for example if a launch, tail, or loopback cord was
not detected during a SmartLoop test, or if the distance to the
end was not the same in both directions.
GPU197.EPS
Figure 158. EventMap for Averaged, Bi-directional SmartLoop Results
The purple fiber is the loopback cord.
The longest segment length of the two directions.
Tap this button to see the results for the other fiber (A or B).
Touch for 3 seconds to see a summary of the results from
ends 1 and 2 on fibers A and B. To see the EventMap for a result
in the list, tap the result.
A
B
I
G
C
D
F
H
E