EasyManua.ls Logo

Fluke Versiv Series - Page 643

Fluke Versiv Series
700 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 21: Specifications
DSX-8000 CableAnalyzer Module Specifications
607
Residual NEXT
1 to 2000 MHz:
90 – 20 log(f/100)
(measured to 90 dB
maximum)
1 to 2000 MHz:
85 - 20 log(f/100)
(measured to 90 dB
maximum)
1 to 500 MHz:
64 - 20 log(f/100)
(measured to 90 dB
maximum)
500 to 2000 MHz:
50.0206 - 45log(f/100)
Residual FEXT
1 to 2000 MHz:
80 - 20 log(f/100)
(measured to 85 dB
maximum)
1 to 2000 MHz:
70 - 20 log(f/100)
(measured to 85 dB
maximum)
1 to 2000 MHz:
43.1 - 20 log(f/100)
(measured to 85 dB
maximum)
Output Signal
Balance
1 to 600 MHz:
40 - 20 log(f/100)
(measured to 40 dB
maximum)
600 to 2000 MHz:
24.4 dB
1 to 600 MHz: 37 - 20 log(f/100)
(measured to 40 dB maximum)
600 to 2000 MHz: 21.4 dB
Common
Mode
Rejection
1 to 600 MHz:
40 - 20 log(f/100)
(measured to 40 dB
maximum)
600 to 2000 MHz:
24.4 dB
1 to 600 MHz: 37 - 20 log(f/100)
(measured to 40 dB maximum)
600 to 2000 MHz: 21.4 dB
Reflection
Tracking
0.5 dB
Directivity
1 to 2000 MHz:
30.7 - 9log(f/100),
30 dB maximum
1 to 300 MHz:
28.7 - 9log(f/100), 30 dB maximum
-continued-
DSX-8000 Level 2G Accuracy Performance Parameters
per IEC Guidelines (continued)
Parameter Baseline Field Tester Field Tester with
Level 2G
Permanent Link
Adapter
Field Tester with
Level 2G Channel
Adapter

Table of Contents

Other manuals for Fluke Versiv Series

Related product manuals