Chapter 21: Specifications
CertiFiber Pro OLTS Module Specifications
621
CertiFiber Pro OLTS Loss/Length Specifications (cont.)
Specification
CertiFiber Pro
Multimode Modules
CertiFiber Pro
Singlemode
Modules
Wavelengths
850 nm, 1300 nm, 1310 nm, 1550 nm
Power measurement range
850 nm: +10 dBm to -65 dBm
All other wavelengths: +10 dBm to -70 dBm
Display Resolution
dB, dBm: 0.01
Linear (nW, μW, mW): 0.001 to 9.999, 10.00 to
99.99, 100.0 to 999.9 depending upon value
Power measurement
uncertainty (accuracy)
 5 % 32 pW
1,2
Measurement linearity
< 0.1 dB
3
Dynamic Range for main-
remote communication and
nominal length measurement
12 dB 26 dB
1.  5 % 100 pW at 850 nm
2. Under the following conditions:
Power level 100 μW (-10 dBm), continuous wave (CW) for absolute power at
850 nm and 1310 nm.
Divergent beam, NA = 0.20 for 50/125 μm and NA = 0.14 for 9/125 μm.
Ambient temperature 23° ± 1 °C.
SC/UPC connector with ceramic ferrule.
After a 5 minute warm-up.
Traceable to NIST.
3. -3 dBm to -55 dBm at 850 nm and 1310 nm. Ambient temperature 23 °C ± 1 °C.
After a 5 minute warm-up.

Table of Contents