55
In the rst window, touch the „i“ key on the
„HEAD.INFO“ button to call up the orbital
welding gun data.
IMPORTANT! The elds contained in this
window are not controls and are for display
purposes only.
- Diameter min. - minimum diameter of the pipe joins to be welded [mm]
- Diameter max. - maximum diameter of the pipe joins to be welded [mm]
- Pulses
- Sync. switch - position in tenths of a degree of the synchronisation switch A value
of 0 means that no synchronisation switch is connected. A value of 3600 means, for
example, that the limit switch is tted at the 360 ° position
- Max. speed - highest rotation speed [cm/min]
- Speed adj. - correction factor for the rotation speed
OFF - no correction factor
- Wire - maximum wire feed speed [cm/min]
The illustration on the left shows the pin
assignment for the welding torch connec-
tion as seen from the front
The table illustrated below shows which
numbers the „torch plug“ eld contains
depending on the pin just activated. The
table also explains the meaning of the
number shown in the „torch plug“ eld for a
welding torch and an orbital welding gun.
1
2
3
4
5
6
7
8
9
Alarms and
device-specic
data
(continued)
Pin Indicator Welding torch Up/Down Orbital welding gun
2 4 Down -
2 5 - Remaining air alarm
3 8 Lower -
3 9 - External stop
4 2 Up -
5 16 Start -
5 17 - External start
8 1/0* Up/Down -
9 - GND GND
* The value becomes 0 when the Pin 8 - Pin 9 (=GND) contact is closed
- Welding torch Up/Down: contact closed
- Orbital welding gun: contact open