56
Controls on the orbital welding gun
(1) (2) (3) (4)
The following illustration shows one possible arrangement of keys on the orbital weld-
ing gun, and to the right of it, information on which pins are activated by them and which
number appears in the display.
WARNING!
Operating the device incorrectly can cause serious injury and damage!
Do not use the functions described here until you have read and completely
understood all of the following documents:
- these Operating Instructions
- all the operating instructions for the system components, especially the
“Safety Rules”
WARNING!
Risk of injury and damage from machines that start up automatically!
Automatically starting machines can cause serious injury and property damage
caused by snagging, pulling or crushing of body parts.
- For your personal safety, ensure that all protective measures have been
implemented and will remain in place while you are within the working area
of the welding system
Nr. Function
(1) Button “Stop / Test”
- To immediately stop the welding
process.
- Hold for 2 sec. for gas test
(2) Button “Rotation”
The torch rotates in the set direc-
tion of rotation.
(3) Button “Start / Stop”
To start and stop the welding
process.
(4) LED limit switch
Signal for the 360 degree position
of the limit swich.
Alarms and
device-specic
data
(continued)