MHP 700i W / R
(0.95 - 2.25 m /
3.12 - 7.38 ft.)
I (ampere) 10 min/40°C
M21 (EN 439)
100% D.C.* / 700
I (ampere) 10 min/40°C
C1 (EN 439)
100% D.C.* / 700
Ø
[mm]
[in.]
0.8-1.6 (0.031-0.063)
[m]
[ft. + in.]
0.95 / 1.10 / 1.25 / 1.45 / 1.75 / 1.95 / 2.25
3.12 / 3.61 / 4.1 / 4.76 / 5.74 / 6.4 / 7.38
P
min
[W] **
0.95 m / 3.12 ft
1.10 m / 3.61 ft
1.25 m / 4.1 ft
1.45 m / 4.76 ft
1.75 m / 5.74 ft
1.95 m / 6.4 ft
2.25 m / 7.38 ft
1200
1300
1300
1400
1600
1800
2000
Q
min
[l/min]
[gal./min]
1
0.26
p
min
[bar]
[psi]
3
43.50
p
max
[bar]
[psi]
5
72.5
* D.C. = Duty cycle
** Lowest cooling capacity in accordance with standard IEC 60974-2, depending on
the length of the hosepack
144