EasyManuals Logo

Fronius TPS/i Push User Manual

Fronius TPS/i Push
152 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #47 background imageLoading...
Page #47 background image
wirefeeding will be stopped and the wire electrode will be retracted again by 1
mm (0.039 in.).
NOTE!
If there is a ground earth connection with the contact tip before the wire threading
button is pressed, the wire electrode will be retracted when the button is pressed
until it is short-circuit-free – it retracts by no more than 10 mm (0.39 in.) with each
press of the button.
If there is still a ground earth connection with the contact tip after 10 mm (0.39 in.) of wire
retraction, pressing the wire threading button again will cause the wire electrode to be
retracted again by a maximum of 10 mm (0.39 in.). The process will be repeated until
there is no longer a ground earth connection with the contact tip.
47