WireSense break
- Single Bit
- This signal only has an impact if the WireSense start signal is active at the same
time
- This signal is used to interrupt the WireSense process but at the same time to obtain
the reference point that was determined when the WireSense process was first star-
ted
The WireSense break signal stops the wire movement while the WireSense
start signal is active - for example, to bridge larger distances between two work-
pieces (if the wire electrode is touching a workpiece while the WireSense break
signal is active, the wire electrode is still retracted to prevent bending)
The reference point, which was determined when the WireSense process was
first started, remains stored while the WireSense break signal is active
After the WireSense break signal is deactivated, the wire movement starts
again and the height measurement continues
- When the WireSense break signal is set, the Arc stable signal is deactivated at the
same time. As soon as the WireSense break signal is deactivated again, the Arc
stable is activated signal again.
For more information on WireSense, see section WireSense - more information on
page 52.