Page #52 background image
WireSense - more information
Process descrip-
tion WireSense
(contour detec-
tion)
WireSense Edge Detection = 0mm
(OFF)
Input: BIT 256 - 271
WireSense start = High (ON)
Input: BIT 29
WireSense position = 0mm
Output: BIT 256 – 271 (max. +/-
24mm)
WireSense position = -5mm
Output: BIT 256 – 271 (max. +/-
24mm)
WireSense position = -7mm
Output: BIT 256 – 271 (max. +/-
24mm)
WireSense start = Low (OFF)
Input: BIT 29
Wait for:
Arc stable = High (ON)
Output Bit 5
Start robot movement for
WireSense action
Wait for:
Arc stable = Low (OFF)
Output Bit 5
For more information on contour detection, see:
- Section WireSense start - Single Bit from page 18 and
- Section WireSense edge detection - Group Input / Analog Input from page 22
and
- Section WireSense break - Single Bit from page 19 and