Current monitor-
ing
Serves to:
- Set the current set value and the desired limits
- Monitor the current actual value per weld seam / job
Current monitoring
Adjustable parameters:
(1) Current set value:
0 to 100 A
(2) Lower current limit:
-10 to 0 A
(3) Upper current limit:
0 to 10 A
(4) Time limit for the reaction of Limit Monitoring:
Off / 0 to 10 seconds
Explanation for setting from 0 to 10 seconds:
- If, for example, 5 seconds are set, Limit Monitoring will only react after a limit
has been exceeded or undershot continuously for 5 seconds
Explanation for "Off" setting:
- Limit Monitoring is disabled for this welding parameter
- There is no display of limit overruns
Possible error messages during current monitoring:
21 | Lower current limit undershot
22 | Upper current limit exceeded
Wirefeeder monit-
oring
Serves to:
- Set the wirefeeder set value and the desired limits
- Monitor the wirefeeder actual value per weld seam / job
68