6.5 List of Messages
247
Troubleshooting
6
016‑752
[Cause] PDF file cannot be printed by using Contents Bridge because of
insufficient memory.
[Action] When using the Contents Bridge Utility, change the [Print Mode] settings
in the [Contents Bridge] dialog box as follows:
●
If [High Quality] is selected, change it to [Standard].
●
f [Standard] is selected, change it to [High Speed].
●
“4.13 Printing PDF Files Directly (ContentsBridge)”(P.88)
●
When printing a PDF file by directly using the lpr command instead
of Contents Bridge, refer to "7.2.1 Print Language Setting" (P.258)
and change the setting on the control panel.
016‑753
[Cause] The password of the PDF file is not consistent with the password
that is specified for the printer or the password that is specified by
the Contents Bridge Utility.
[Action] Specify the correct password for the printer or for the Contents
Bridge Utility, and try to print again.
016‑754
[Cause] PDF file contains an LZW compression applied object. It cannot be
printed unless the optional Contents Bridge Extension Kit is installed.
[Action] Try to print in the following way:
●
Open the PDF file from Adobe Acrobat Reader, and try to print
by selecting [Print] on the [File] Menu.
●
It is recommended to install the Contents bridge Extension Kit if
you intend to frequently print PDF files that contain an LZW
compression applied object by Contents Bridge.
016‑755
[Cause] A PDF file cannot be printed unless printing is permitted.
[Action] Enable PDF file printing by using Adobe Acrobat, and try to print again.
016‑757
[Cause] The input password is incorrect.
[Action] Input the correct password.
016‑758
[Cause] Not registered as a service user department.
[Action] Consult with the meter administrator.
016‑759
[Cause] The number of printed pages reached the upper limit for service.
[Action] Consult with the meter administrator.
Error code Cause/action