Chapter 6 RAID Group Status
6.3 Eco-mode Schedule (RAID Group)
ETERNUS Web GUI User’s Guide (Operation)
Copyright 2016 FUJITSU LIMITED P2X0-1260-19ENZ0
314
- Standard / WSV
A RAID group that is used for creating the following volumes:
• "WSV" and "Standard"
• "WSV" and "SDV"
• "WSV" and "SDPV"
- WSV
A RAID group that is used for creating "WSV" type volumes
• RAID Level
The RAID level is displayed.
- High Performance (RAID1+0)
- High Capacity (RAID5)
- High Reliability (RAID6)
- High Reliability (RAID6-FR)
- Reliability (RAID5+0)
- Mirroring (RAID1)
- Striping (RAID0)
• Total Capacity
The total capacity of the RAID groups is displayed.
• Eco-mode Schedule
The Eco-mode schedule name that is assigned to the RAID group is displayed. If the Eco-mode is controlled
with Storage Foundation Software ETERNUS SF, "External" is displayed. When no Eco-mode schedule has
been assigned, the field is blank.
• Eco-mode Action
The Eco-mode schedule action status is displayed.
When no Eco-mode schedule has been assigned, a "-" (hyphen) is displayed.
- Drive power off
The power for the drive is turned off during Eco-mode operation.
- Drive motor off
The drive motor is stopped during Eco-mode operation.
- Drive always on
Disable Eco-mode and the drive is always active.
• Motor Status
The drive motor status is displayed.
- Active
The drive motors are activated.
- In the Boot Process
The drive motors are starting up.
- Idle
The drive motors are stopped.
- In the Stop Process
The drive motors are being stopped.
- Power off
The drive power is being turned off.