Chapter 3 Component Status
3.2 Controller Enclosure
ETERNUS Web GUI User’s Guide (Operation)
Copyright 2016 FUJITSU LIMITED P2X0-1260-19ENZ0
91
3.2.6 PCIe Flash Module
This function displays the PCIe Flash Module (PFM) information.
For the ETERNUS DX8700 S3/DX8900 S3
If a PFM is not available for reading and writing, " Error" is displayed for the status. If this occurs, replace
the PFM. Note that PFMs can be replaced by a maintenance engineer who has the "Maintenance Operation"
policy.
PFMs can be installed in the ETERNUS DX500 S3/DX600 S3 and the ETERNUS DX8700 S3/DX8900 S3.
If the PFM capacity in each CM for the ETERNUS DX500 S3/DX600 S3 does not match, the EXC memory size
that can be used for the CM is reduced to the smallest capacity.
For the ETERNUS DX8700 S3/DX8900 S3, the PFM capacity in each CM is used as an EXC memory size.