80209C_MHW_850-1650-1850_02-2020_ENG_pag. 159
4.23.10. TIMER - Timer value
Acronym Scrolling message Submenu Attributes
TIMER TIMER.1 (o TIMER.2) ACTUAL TIME TIMER R W
The parameter shows and sets the timer value.
Unit of measurement: Minutes or Seconds according to the selection set in the MODE submenu, parameter tMEr
Options: 0...9999
4.23.11. MSG.TM - Selecting message assigned to end of count
Acronym Scrolling message Submenu Attributes
MSG.TM TIMER.1 (o TIMER.2) MSG NUMBER WHEN TIMER OVER TIMER R W
The parameter shows and sets the number of the message assigned to end of count condition of the timer, i.e. the scrol-
led message seen on the display.
For more information on scrolling messages, see paragraph “3.1.2.2. Scrolling messages” on page <?>.
If the parameter is set to “0” no message will be displayed at the end of the timer count.
Unit of measurement: Message number
Options: 0...25 (with LAnG=LANG1 or LANG2 or LANG3)
0…75 (with LAnG=NONE)