ADL300 • Functions description and parameters list 15
Menu PAR Description UM Type FB BIT Def Min Max Acc Mod
4.4 566 Passwd expert UINT32 0 0 99999 RW FVS
EASY (default)
EXPERT
SERVICE
PAR 554=1
CHECK PSWD
SET PSWD
S
PAR 554
0 Easy
1 Expert
Access Mode
PAR 586
XXXX
Default = 0 (No password)
Set psswd expert
PASSWORD SERVICE
XXXX
Switch OFF
Switch ON
Switch OFF
Switch ON
Switch OFF
Switch ON
Wrong
PAR 566
XXXX
Default = 0 (No password)
Password expert
PAR 566 = PAR 586
(1) (2)
(1) or (2) depending of last saving
Type the password to enable parameter 554 Access mode.
The password must have been entered via parameter 586 Set passwd expert.
Menu PAR Description UM Type FB BIT Def Min Max Acc Mod
4.5 Reserved
Menu PAR Description UM Type FB BIT Def Min Max Acc Mod
4.6 558 Application select ENUM Application 1 0 2 ERWZ FVS
Selection of which IEC 61131-3-compliant application to make operational.
0 None
1 Application 1 (EFC, see menu 5 - LIFT)
2 Application 2 (EPC, see manual 1S9EPEN ADL300-EPC)
The drive is supplied already incorporating a number of applications developed in the IEC 61331-3 environment. In the
default conguration the drive starts with the EFC lift application (see menu 5 - LIFT for the description of this application).
To use the Application 2 (EPC), congure PAR 558 =2, run PAR 550 Save parameters, switch the drive o󰀨 and then on
again.
Note! The Load Default command (par. 580) does not modify this parameter
Menu PAR Description UM Type FB BIT Def Min Max Acc Mod
4.7 560 Mains voltage V ENUM 400 V SIZE SIZE ERWZS FVS
Setting of the available mains voltage value in Volts. Detection of the undervoltage alarm refers to this value.
0 200 V
1 230 V (default ADL300-...-2M)
2 380 V
3 400 V
4 415 V
5 440 V
6 460 V
7 480 V
8 575 V
9 690 V
Menu PAR Description UM Type FB BIT Def Min Max Acc Mod
4.8 448 Emergency UV V FLOAT CALCF 0.0 CALCF ERWZ FVS
This parameter enables for the undervoltage threshold to be congured during emergency conditions.