ADL300 • Functions description and parameters list 51
Menu PAR Description UM Type FB BIT Def Min Max Acc Mod
5.9.4 11204 Brake activity INT16 1 0 5 RW FVS
Setting of drive behaviour in case of a Brake fbk fail alarm. This alarm indicates that the feedback conrming opening/clos-
ing of the brake has not been received.
0 Ignore
1 Warning
2 Disable
3 Fast Stop
4 Lift Fast stop
5 Lift stop
Menu PAR Description UM Type FB BIT Def Min Max Acc Mod
5.9.5 11206 Brake hold off ms INT32 3000.00 RW FVS
Setting of the delay time between activation of the Brake fbk fail alarm condition signal and the actual alarm. In case of an
alarm condition, the drive waits for the set time to elapse before activating the alarm. If the alarm is removed within the set
time, the drive will not activate the alarm.
Menu PAR Description UM Type FB BIT Def Min Max Acc Mod
5.9.6 11208 Brake run hold off INT16 1 0 1 RW FVS
Setting of drive behaviour when a possible Brake fbk fail alarm is detected.
0 Disable
1 Enable
If set to 0 the brake feedback alarm is indicated immediately
If set to 1 the possible brake feedback alarm is indicated at the end of travel: this allows the cabin to reach the oor in case
of a faulty brake status signal.
Menu PAR Description UM Type FB BIT Def Min Max Acc Mod
5.9.7 11210 Door activity INT16 1 0 5 RW FVS
Setting of drive behaviour in case of a Door fbk fail alarm. This alarm indicates that the feedback conrming opening of
the door has not been received.
0 Ignore
1 Warning
2 Disable
3 Fast Stop
4 Lift Fast stop
5 Lift stop
Menu PAR Description UM Type FB BIT Def Min Max Acc Mod
5.9.8 11212 Door hold off ms INT32 1000 RW FVS
Setting of the delay time between activation of the Door fbk fail alarm condition signal and the actual alarm. In case of an
alarm condition, the drive waits for the set time to elapse before activating the alarm. If the alarm is removed within the set
time, the drive will not activate the alarm.
Door open mon
Door fbk src
No Alarm
Alarm Door fbk fail
Hold
off
Door
Door open src
Speed
Door open speed
Menu PAR Description UM Type FB BIT Def Min Max Acc Mod
5.9.9 11214 Limit activity INT16 5 0 5 RW FVS

Table of Contents

Other manuals for gefran SIEIDrive ADL300

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the gefran SIEIDrive ADL300 and is the answer not in the manual?

gefran SIEIDrive ADL300 Specifications

General IconGeneral
Brandgefran
ModelSIEIDrive ADL300
CategoryInverter
LanguageEnglish

Related product manuals