Displays the number of direction changes remaining on the previous set of ropes (value of PAR 3414 Direction counter is
copied before reset). This number will remain xed until the next replacement of the ropes.
Menu PAR Description UM Type FB BIT Def Min Max Acc Mod
20.9.10 3418 No of cnt reset UINT32 32BIT 0 0 0 ER FVS
Displays the number of rope changes made.
Menu PAR Description UM Type FB BIT Def Min Max Acc Mod
20.9.11 3420 Ropes change req mon BIT 16BIT 0 0 1 ER FVS
Activates when the percentage of rope usage (set in PAR 3412 Ropes usage) exceeds the set threshold (PAR 3404
Ropes change thr).
This signal is inserted in the L_DIGSEL1 selection list and can be brought to a digital output.
Menu PAR Description UM Type FB BIT Def Min Max Acc Mod
20.9.12 3434 Save to keypad BIT 0 0 1 ERWZ FVS
Lets you save the conguration of the “Direction change count” function on the keypad.
The set of parameters is saved in a dedicated area on the keypad, separate from that of the other parameters (PAR 590
Save par to keypad).
Menu PAR Description UM Type FB BIT Def Min Max Acc Mod
20.9.13 3436 Load from keypad BIT 0 0 1 ERWZ FVS
Lets you load the conguration of the “Direction change count” function saved on the keypad with PAR 3434 Save to key-
pad on the new drive.