MagicControl 4.0 (CM40) Operation
43
Working interruptions or coating breaks
If the coating process is interrupted for a longer period of time, the system
should be brought into an economical state.
Switching off the plant
1. Clean the plant, See chapter "Cleaning operation mode" on page 40.
2. To exit Cleaning mode, press and hold the key for 2
seconds.
Fig.
28
:
3. The display changes to this screen
Fig.
29
:
4. Turn the key switch to 0 to turn off the control voltage.
The indicator lamp goes out.