98
After filter pressure monitoring MagicControl 4.0 (CM40)
ID no.
Setting values / range
Default
UL
1561
0 2000[m]
500[m]
g0
1562 Temperature
This parameter must be adjusted according to the ambient temperature in
which the filter is installed. The exhaust air is automatically adjusted
depending on the temperature.
A higher temperature means thinner air and therefore a higher exhaust air
level is required.
ID no.
Setting values / range
Default
UL
1562
5 40[ºC]
20[ºC]
g0