8.5 Error Messages
Operation
8.5 Error Messages
Device faults and malfunctions are shown abbreviated in white text in red fields in the AUTO
main menu, warnings flash. Information on the cause of fault can be found in the corresponding
menus in the "GAV Settings" area.
Error message
Submenu
Remedy
Navigation
Vibration feed unit
Vibration Feed Unit Settings
Lack of blind rivets.
Top up blind rivets or check vi-
bration feed unit settings.
►MAN
►Menu
►GAV settings
►Vibration feed unit
System pressure:
DS1/DS2 Pressure Sensor Settings
Air supply is not in permissible
pressure range.
Secure adequate compressed
air supply.
►MAN
►Menu
►GAV settings
►Pressure sensors
Oil level
WS2 Large Pressure Booster Settings
Oil level in the large pressure
booster has dropped below the
minimum mark or exceeded the
maximum mark.
Correct oil level in large pres-
sure booster, observe oil level
mark.
►MAN
►Menu
►GAV settings
►Large pressure booster
►WS2
Oil level in the small pressure
booster has dropped below the
minimum mark.
WS3 Small Pressure Booster Settings
Use oil can to move piston rod
to upper end position.
►MAN
►Menu
►GAV settings
►Small pressure booster
Riveting gun
WS2 Large Pressure Booster Settings
GAV gun has not reached
front end position.
See Section 20 "Riveting Gun
Faults".
►MAN
►Menu
►GAV settings
►Large pressure booster
►WS2
8
- 23 -
Navigation:
AUTO
AUTO main menu
Status "Home position"
3 error messages

Table of Contents