8.5 Error Messages
Operation
8.5 Error Messages
Error message
Submenu
Remedy
Navigation
Nosepiece
WS3 Small Pressure Booster Settings
Spreader nosepiece of GAV gun
was not closed.
- Press OFF button.
- Remove blind rivet.
- Press ON button.
►MAN
►Menu
►GAV settings
►Small pressure booster
Separator
Separator Settings
Separator was not closed, blind
rivet jammed.
Open separator in MAN mode
and remove blind rivet.
►MAN
►Menu
►GAV settings
►Separator
Mandrel evacuation
Mandrel Evacuation Settings
Spent mandrel was not ejected.
See Section 20 "Riveting Gun
Faults".
►MAN
►Menu
►GAV settings
►Mandrel evacuation
Mandrel container full
Mandrel Evacuation Settings
Spent mandrel container full.
Empty spent mandrel contain-
er.
►MAN
►Menu
►GAV settings
►Mandrel evacuation
Rivet check nosepiece
PLC Activation Settings
Blind rivet was not loaded.
See Section 20 "Riveting Gun
Faults".
►MAN
►Menu
►GAV settings
►PLC activation
Rivet check feed hose
Additional Functions Settings
Blind rivet was not fed in.
See Section 20 "Riveting Gun
Faults".
►MAN
►Menu
►GAV settings
►Additional functions
Cycle
Cycle Settings
Cycle error, blind rivet was not
processed.
See Section 20 "Riveting Gun
Faults".
►MAN
►Menu
►GAV settings
►Cycle
8
- 24 -