8.5 Error Messages
Operation
8.5 Error Messages
Direct menu selection:
To simplify the search for the required menu with information of the cause of fault and to there-
fore shorten the navigation path, the selection can be switched to the displayed error messages
with ? in the main menu. The corresponding menu then opens directly after selecting an er-
ror message and pressing the rotary knob. You return to the main menu by pressing Back.
Example:
In the illustrated example, the "WS2 Large Pressure Booster Settings" menu is opened directly
with ? and selecting "Error - oil level". Here the setting parameter "Error - min. oil level" is
marked in red as the cause of the fault, the current oil level in the oil reservoir of the large pres-
sure booster is displayed in numeric and graphic form.
In the illustrated example, the fault can be rectified by topping up the hydraulic oil in the large
pressure booster. The numeric and graphic display of the oil level allows you to observe the re-
filling procedure on the display.