8.7 Manual Operation
Operation
8.7 Manual Operation
GAV functions can be executed manually in the MAN menu. Device faults are displayed in the
same way as in the AUTO main menu, however, they are not start conditions. For safety rea-
sons, the active start options in the AUTO main memory are blocked in the entire manual
area.
Function
Description
Cycle
- Condition: GAV in home position.
- One complete processing cycle is executed.
Stroke position
- Condition: GAV in home position.
- Gun is moved to rear end position, the functions "Gun air OFF", "Blow
air ON" and "Mandrel evacuation ON" are not executed.
- Press again or ON button to reset GAV to home position, the functions
"Blow air OFF", "Lock open" and "Separator open" are not executed.
Blow air
- Condition: "Stroke position" function active.
- "Blow air ON" function is activated.
- "Mandrel evacuation ON" function is activated.
- "Gun air OFF" function is activated.
Mandrel evacua-
tion
- Condition: None.
- "Mandrel evacuation ON" function is activated.
- Press again or ON button to reset the function.
Lock open
- Condition: GAV in home position.
- "Lock open" function is activated.
- Press again or ON button to reset the function.
Separator open
- Condition: GAV in home position.
- "Separator open" function is activated.
- Press again or ON button to reset the function.
Vibration feed unit OFF / ON
Same function as in AUTO main menu.
Stby
Same function as in AUTO main menu.
MAN
Opens the MAN menu for manual operation.
Menu
Opens the selection menu.
AUTO
Back to AUTO main menu.
8
Navigation:
AUTO
►MAN
MAN manual operation
- 27 -