6-15
Chapter 6 Maintenance
6.11 Cleaning Separator Suppression Unit
When media glue or refuse collects on the brush section of the separator suppression unit and separation (refuse
collection) takes place, there is the possibility of it not becoming unstuck.
"Close cut mark read errors" will frequently occur.
In the case described above, clean the brush section of the separator suppression unit.
Cleaning
(1) Remove dancer roller 2 from the separator side and open the separator section. (Steps 1 & 2)
Keep the separator suppression unit open. (Step 3)
Always remove the dancer roller before opening the separator.
Separator Suppression unit
Separator
Brush
Step 2
Dancer roller 2
Step 1
Step 3
(2) With the separator suppression unit open, remove the refuse or debris attached to the top of the brush section.
(3) After cleaning, return it to its original state.