11
[DeviceC-Twenty-FiveGigE1/0/2] port trunk permit vlan all
# Enable MVRP on Twenty-FiveGigE 1/0/2.
[DeviceC-Twenty-FiveGigE1/0/2] mvrp enable
[DeviceC-Twenty-FiveGigE1/0/2] quit
4. Configure Device D:
# Enter MST region view.
<DeviceD> system-view
[DeviceD] stp region-configuration
# Configure the MST region name, VLAN-to-instance mappings, and revision level.
[DeviceD-mst-region] region-name example
[DeviceD-mst-region] instance 1 vlan 10
[DeviceD-mst-region] instance 2 vlan 20
[DeviceD-mst-region] revision-level 0
# Manually activate the MST region configuration.
[DeviceD-mst-region] active region-configuration
[DeviceD-mst-region] quit
# Globally enable the spanning tree feature.
[DeviceD] stp global enable
# Globally enable MVRP.
[DeviceD] mvrp global enable
# Configure Twenty-FiveGigE 1/0/1 as a trunk port, and configure it to permit VLANs 20 and 40.
[DeviceD] interface twenty-fivegige 1/0/1
[DeviceD-Twenty-FiveGigE1/0/1] port link-type trunk
[DeviceD-Twenty-FiveGigE1/0/1] port trunk permit vlan 20 40
# Enable MVRP on Twenty-FiveGigE 1/0/1.
[DeviceD-Twenty-FiveGigE1/0/1] mvrp enable
[DeviceD-Twenty-FiveGigE1/0/1] quit
# Configure Twenty-FiveGigE 1/0/2 as a trunk port, and configure it to permit VLAN 40.
[DeviceD] interface twenty-fivegige 1/0/2
[DeviceD-Twenty-FiveGigE1/0/2] port link-type trunk
[DeviceD-Twenty-FiveGigE1/0/2] port trunk permit vlan 40
# Enable MVRP on Twenty-FiveGigE 1/0/2.
[DeviceD-Twenty-FiveGigE1/0/2] mvrp enable
[DeviceD-Twenty-FiveGigE1/0/2] quit
Verifying the configuration
1. Verify the normal registration mode configuration.
# Display local VLAN information on Device A.
[DeviceA] display mvrp running-status
-------[MVRP Global Info]-------
Global Status : Enabled
Compliance-GVRP : False
----[Twenty-FiveGigE1/0/1]----
Config Status : Enabled
Running Status : Enabled
Join Timer : 20 (centiseconds)
Leave Timer : 60 (centiseconds)