Maintenance
Ma i n t e n a n c e
General Requirements
Operating Temperature Range: 41°F to 104°F (5 to 40°C)
Storage Temperature Range: -4°F to 158°F (-20 to 70°C)
Ambient Humidity: 20% – 95% relative humidity, non-condensing
Altitude: 0-7000 ft.
el e c t r i c i t y re Q U i r e M e n t S
All Machines Require:
AC input power is three phase Delta or Wye power, except that the power
source must be grounded (e.g. leg or center leg for delta, neutral for Wye)
Frequency range of 47-66 Hz
Line voltage that does not uctuate more than ± 10%
Harmonic distortion not to exceed 10% of the total RMS voltage
20-15 HP System (Standard VF and 10K, EC300, EC400)
195-260V Voltage 54-488V High-Voltage
Power Supply 1 50 AMP 25 AMP
Haas Circuit Breaker 40 AMP 20 AMP
If service run from elec.
panel is less than 100’ use:
8 GA. WIRE 12 GA. WIRE
If service run from elec.
panel is more than 100’ use:
6 GA. WIRE 10 GA. WIRE
40-30 HP System (50 Taper, 40 Taper HT 10K, VF Super Speed, EC-300, EC-400
12K, VM)
195-260V Voltage 354-488V High-Voltage2
Power Supply1 100 AMP 50 AMP
Haas Circuit Breaker 80 AMP 40 AMP
If service run from elec.
panel is less than 100’ use:
4 GA. WIRE 8 GA. WIRE
If service run from elec.
panel is more than 100’
use:
2 GA. WIRE 6 GA. WIRE
40-30 HP System (VS 1/3, HS 3-7 incl R models)
195-260V Voltage
Power Supply 125 AMP
Haas Circuit Breaker 100 AMP
If service run from elec. panel is
less than 100’ use:
2 GA. WIRE
If service run from elec. panel is
more than 100’ use:
0 GA. WIRE