247
96-8000 Rev AC
May 2010
Maintenance
TSC1000 Maintenance
Before doing any maintenance to the 1000psi system, disconnect the
power source; unplug it from the power supply.
.
Double
Lid
Standard
Pump
TSC
Pump
Auxiliary
Filter
Gate Filter
Replacement
Filters
TSC1000/HPC1000
Check the oil level on a daily basis. If the oil is low, add oil through the ll cap
on the reservoir. Fill the reservoir about 25% full with 5-30W synthetic oil.
Auxiliary Filter Element Replacement
Change the lter bag when the lter gauge displays a vacuum level of -5 in. Hg
or more. Do not allow the suction to exceed -10 in. Hg or pump damage may
occur. Replace with a 25-micron rated lter bag (Haas P/N 93-9130).
Loosen the clamps and open the lid. Use the handle to remove the basket
(the lter element will be removed with the basket). Remove the lter element
from the basket and discard. Clean the basket. Install a new lter element and
replace the basket (with element). Close the lid and secure the clamps.