23
A2-26
Technical information
Data Value Unit
Min. volume flow*) 570 m³/h
*) Data taken from the volume flow at 20 m/s.
4.7 Dust emission
T
he working areas of this machine are considered dust-minimised according to
DGUV Information 209-044. The maximum concentration level of 2 mg/m³ of
inhalable dust in the air will not be exceeded. This only applies if the conditions
that are specified in the section "Extraction" are adhered to.
4.8 Noise level
Note on measurement
If the stated noise emission values are to be checked, then the measurements must
be taken following the same procedure and in the same operating and installation
conditions as described.
All values in dB(A) and with a measurement uncertainty factor of 4 dB(A). Meas-
urement conditions and additional information according to ISO 19085-1:2021,
chapter 6.2.2.
The measurements are carried out in accordance with the following standards:
ISO 7960:1995, annexure B (planers)
ISO 7960:1995, annexure C (thicknessers)
EN ISO 3746, acoustic power level
EN ISO 11202, workplace emission values
N
oise emission values when planing
Idle Working
Acoustic power level - L
W
A
(EN ISO 3746)
101 dB (A) 103 dB (A)
Workplace emissions values - L
pA
(EN IS
O 11202)
87 dB (A) 88 dB (A)
Noise emission values when thickness planing
Idle Working
Acoustic power level - L
W
A
(EN ISO 3746)
99 dB (A) 101 dB (A)
Workplace emissions values - L
pA
(EN ISO 11202)
Working position 1 (infeed) 89 dB (A) 90 dB (A)
Working position 2 (outfeed) 89 dB (A) 93 dB (A)