Maintenance
Alternatively, machines without a separate feed motor can be
eq
uipped with red
[Stop]
buttons instead of the
[Emergency Stop]
buttons.
Carry out emergency stop test with all red [Stop] buttons on the
machine.
Test the emergency stop if the machine is equipped with an
[emergency stop]
button
1.
Prepare the machine to operate.
2.
Switch machine on.
3.
Push the [Emer
gency stop].
Machine will stop immediately.
Continue with next step.
Machine does not stop immediately.
If present: Switch off [Main s
witch] (position "O" / "OFF").
Disconnect the machine from the mains power supply.
Contact Felder Group-service.
4.
Switch the machine on using the green [s
tart] button with the [emergency
stop] button locked.
machine does not start.
Unlock the [Emer
gency stop] button by turning it.
Repeat with all [Emer
gency Stop] buttons on the machine.
Machine can not be started.
Press the red [S
top] button.
If present: Turn the [main s
witch] off (position "O" / OFF) and secure
it.
Contact Felder Group-service.
T
est the red stop button as the emergency stop if the machine is not equipped with an
[emergency stop]
button
1.
Prepare the machine to operate.
2.
Switch machine on.
3.
Press the red [S
top] button.
Machine will stop immediately.
Repeat the test on the next red [S
top] button.
Repeat with all red [S
top] buttons on the machine.
Machine does not stop immediately.
If present: Switch off [Main s
witch] (position "O" / "OFF").
Disconnect the machine from the mains power supply.
Contact Felder Group-service.