Harris Corporation Constellation™
Field-Replaceable Units 12-17
FIELD-
REPLACEABLE
UNITS
Ensure that the Multiplier-Filter you are installing
is the correct option.
4. Reverse the previous three steps to install the Multiplier-Filter onto the
Receiver Assembly.
Removing and Installing the IF Filter
1. Gently unscrew the SMA connectors. See Figure 12-10.
2. Carefully move the cables out of the way.
3. Loosen the mounting screws to remove the mounting bracket and IF Filter
from the board.
4. Loosen the SMA nuts on the connector to remove the IF Filter from the
mounting bracket.
5. Insert the replacement IF Filter into the mounting bracket.
If IN and OUT are marked on the IF Filter, ensure that the side marked IN
is in the top position as shown in Figure 12-10.
6. Reverse the first four steps to install the IF Filter onto the board.
To prevent damage to the connectors, do not exceed 8
to 9 in-pounds of torque.
Option Bandwidth
(MHz)
-001 5.0
-002 10.0