Harris Corporation Constellation™
Installation and Commissioning 4-15
INSTALLATION AND
COMMISSIONING
2xDS3 + 28 DS1
Figure 4-9: Interconnection cabling, 2xDS3 + 28 DS1
configuration
155 Electrical or Optical configuration
Figure 4-10: Interconnection cabling, 155 Electrical or Optical
configuration
For connector pinout information, refer to Appendix A.
1. Connect the Constellation radio to other equipment.
Refer to Appendix A for pinout information.
2. Connect the customer-configured alarm wires.
All Constellation radios, in terminal or repeater (when applicable)
configuration, provide 8 alarm inputs and 8 relay outputs. These 8 relays can
either provide information about the radio to a non-FarScan NMS, or be used
to activate (from FarScan) external devices such as a generator, air
conditioning, and so forth (housekeeping). These 8 relays are programmable;
the first two relays are predefined at the factory as LOCAL MAJOR and LOCAL
MINOR but can be programmed for customer use.
Radio
Modem
HLM
DS3-2
or
DS3
Jackfield
DS1 Radio
Repeater
DS3 Multiplexer
Application 1
Application 2
or
or
DS3-1
M12
Units
28 DS1
For DS3: Avaya 734 cables, or equivalent.
For DS1: See
Table 4-9.
Radio
Modem
HLM
or
Application 1
Application 2
or
For STM1/STS3: Avaya 734 cables, or equivalent.
For OC3: Single-mode or multimode with SC connectors.