30 – 600 HEIDENHAIN Service Manual iTNC 530
MP2555.x Only CC 424(B): Center/corner frequency for filter 4
Input: 0 to 30000.0 [Hz]
PLC
RUN
MP2556.x Only CC 424(B): Center/corner frequency for filter 5
Input: 0 to 30000.0 [Hz]
PLC
RUN
MP2560.x Low-pass filter
Input: 0: No low-pass filter
1: 1st-order low-pass filter
2: 2nd-order low-pass filter
PLC
RUN
MP2560.x Only CC 424(B): Filter order of the low-pass filter
Input: 0 to 20
340 420-09
PLC
RUN
MP2562.x Only CC 424(B): Filter type for filter 1
Input: 0: No filter
1: PT2 low-pass filter (speed controller)
2: Band-rejection filter (speed controller)
3: Phase increase (speed controller)
11: PT2 low-pass filter (position controller)
12: Band-rejection filter (position controller)
13: Phase increase (position controller)
PLC
RUN
MP2563.x Only CC 424(B): Filter type for filter 2
Input: 0: No filter
1: PT2 low-pass filter (speed controller)
2: Band-rejection filter (speed controller)
3: Phase increase (speed controller)
11: PT2 low-pass filter (position controller)
12: Band-rejection filter (position controller)
13: Phase increase (position controller)
PLC
RUN
MP2564.x Only CC 424(B): Filter type for filter 3
Input: 0: No filter
1: PT2 low-pass filter (speed controller)
2: Band-rejection filter (speed controller)
3: Phase increase (speed controller)
11: PT2 low-pass filter (position controller)
12: Band-rejection filter (position controller)
13: Phase increase (position controller)
PLC
RUN
MP2565.x Only CC 424(B): Filter type for filter 4
Input: 0: No filter
1: PT2 low-pass filter (speed controller)
2: Band-rejection filter (speed controller)
3: Phase increase (speed controller)
11: PT2 low-pass filter (position controller)
12: Band-rejection filter (position controller)
13: Phase increase (position controller)
PLC
RUN
MP2566.x Only CC 424(B): Filter type for filter 5
Input: 0: No filter
1: PT2 low-pass filter (speed controller)
2: Band-rejection filter (speed controller)
3: Phase increase (speed controller)
11: PT2 low-pass filter (position controller)
12: Band-rejection filter (position controller)
13: Phase increase (position controller)
PLC
RUN
MP2572.x Only CC 424(B): Bandwidth for filter 1
Input: 0 to 30000.0 [Hz]
PLC
RUN
MP Function and input SW version
and
behavior