Steps
1. Go to
Conguraon → Event → Smart Event → Object Removal Detecon .
2. Check Enable.
3.
Oponal: Click Lock to lock PTZ control to prevent the interrupon from other PTZ related
acon during conguraon.
Normally, the PTZ control is automacally locked when you enter the conguraon interface.
You can manually resume the lock when the countdown is over.
4. Adjust the live image to the desired scene by using PTZ control
buons.
5. Draw detecon area.
1) Select a Region No.. Up to 4 regions can be set.
2) Click
Detecon Area.
3) Click on the live image to draw the boundaries of the
detecon area, and right click to
complete drawing.
6. Set detecon parameters.
Sensivity The value of the sensivity denes the size of the object which can trigger the
alarm, when the sensivity is high, a very small object can trigger the alarm.
Threshold The threshold is the me of the objects removed from the area. If you set the
value as 10, alarm is triggered aer the object disappears from the area for 10
seconds.
Figure 9-8 Draw Area
7. Click Save.
8. Repeat above steps to set other regions.
9. Set arming schedule. See Set Arming Schedule .
10. Set linkage method. See Linkage Method
Sengs .