5.2 Setting on the Measurement Setting Screen (MEASUREMENT)
57
1
2
3
4
5
6
7
8
9
10
11
5.2.1 Setting the Wiring Method
3P3W2M and 3P3W3M
The active power measurement results will be the same regard-
less of whether measurement is conducted by 3P3W2M (i.e., 2-
voltage, 2-current, 2-power-meter method) or 3P3W3M (i.e., 3-
voltage, 3-current, 3-power-meter method). When 3P3W2M is
selected, U3 and I3 will be calculated based on the U1, U2, or I1,
I2 measurements.
Press the
SET UP
key to display the setting screen.
Press the
F5
(NEXT SCR) key to display the measurement setting
screen. (3169-20: SET UP 1/4, 3169-21: SET UP 1/5)
Move the cursor to "
WIRING
."
Press the
F1
(change) key to display the selection window.
Select a wiring method by using the cursor key.
Press the
F1
(select) key.
1P2W
Measurement of a single-phase, 2-wire line
1P3W
Measurement of a single-phase, 3-wire line
3P3W2M
Measurement of a three-phase, 3-wire line (by the two-
power-meter method)
*:
Select this method to measure three-phase power by
measuring the current at two positions only.
3P3W3M
Measurement of a three-phase, 3-wire line (by the
three-power-meter method)
3P4W
Measurement of a three-phase, 4-wire line
3P4W4I
Measurement of a three-phase, 4-wire line (used for
neutral conductor measurement)
NEXT
SCR
change