62
5.2 Setting on the Measurement Setting Screen (MEASUREMENT)
5.2.4 Setting the Display Average Times
• The display averaging times is the number of moving averages
calculated for instantaneous values (i.e., instantaneous mea-
surements excluding harmonics).
• The moving average is obtained by totaling the set number of
measurements and dividing the sum by the set number. After
the set number of measurements have been acquired, the
3169-20/21 discards the oldest measurement data every time
it acquires new measurement data, and continues to average
the set number of measurements.
Value to be displayed on-screen = (Z
(n - (N - 1))
+ Z
(n - (N - 2))
+ ... +
Z
n
)/N
Z
n
: The nth measurement
N: Set number
If measurements fluctuate drastically, use the averaging func-
tion to stabilize the values displayed on-screen.
Press the
SET UP
key to display the setting screen.
Press the
F5
(NEXT SCR) key to display the measurement setting
screen. (3169-20: SET UP 1/4, 3169-21: SET UP 1/5)
Move the cursor to "
AVERAGE TIMES
."
Press the
F1
(change) key to display the selection window.
Select a display averaging times by using the cursor key.
Press the
F1
(select) key.
1 (default), 2, 5, 10, 20 times
NEXT
SCR
change
select