Basic Settings
RM Web L3P
Release
4.1
03/08
2.1
System
19
Figure 5: Device status and alarm display
System data
This area of the website displays the system parameters of the device.
Here you can change,
the system name,
the location description,
the name of the contact person for this device,
the availability of the media modules (see fig. 6) and
the temperature threshold values.
Name Meaning
Name System name of this device
Location Location of this device
Contact person Contact person for this device
Basic module Hardware version of the basic module
Media module 1 Hardware version of media module 1
Media module 2 Hardware version of media module 2
Media module 3 Hardware version of media module 3
Media module 4 Hardware version of media module 4
Media module 5 Hardware version of media module5
Media module 6 Hardware version of media module 6
Media module 7 Hardware version of media module 7
Power supply (P1/P2) Status of the power supply units
Operating time Time that has elapsed since the device was last restarted.
Temperature Temperature in the device. Lower/upper temperature thresh-
old values. If the temperature goes outside this range, the
device generates an alarm message.
Table 1: System data
Time of the oldest existing alarm
Cause of the oldest existing alarm
Symbol indicates the Device Status