EasyManua.ls Logo

Hisense AVWT-192FFFH - User Manual

Hisense AVWT-192FFFH
317 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
TCY12020008D
TCY12020008D
TCY12020008D
VRF AIR-CONDITIONER (HEAT RECOVERY)
AVWT-72FFFH
AVWT-96FFFH
AVWT-120FFFH
AVWT-144FFFH
AVWT-168FFFH
AVWT-192FFFH
AVWT-216~ 456FFFH
Date: April. 2023
Qingdao Hisense Hitachi Air-conditioning Systems Co.,Ltd.
Add.: No. 218, Qianwangang Road, Economic and Technological Development Zone, Qingdao, China
http://www.hisensehvac.com E-mail: export@hisensehitachi.com
Specications in this catalogue are subject to change without notice, in order that Hisense may
bring the latest innovations to their customers.
BASIC MODELS
COMBINATION MODELS
Technical, Installation
and Service Handbook
VRF AIR-CONDITIONER
HEAT RECOVERY
Hi-FLEXi S
SERIES (208V)

Table of Contents

Questions and Answers

Summary

Hisense VRF Air Conditioner General Data

Hisense VRF Safety and Control Device Settings

Explains settings for compressor protection devices like high-pressure switches and oil heaters.

Hisense VRF Piping System

Hisense VRF Refrigerant Pipe Connection - 3 Pipe Heat Recovery

Details pipe sizes and connection methods for 3-pipe heat recovery systems.

Hisense VRF Refrigerant Pipe Connection - 2 Pipe Heat Pump

Details pipe sizes and connection methods for 2-pipe heat pump systems.

Hisense VRF Additional Refrigerant Charge Calculation

Explains how to calculate and charge additional refrigerant for the system.

Hisense VRF Capacities and Selection Data

Hisense VRF System Selection Procedure

Guides users through selecting the appropriate outdoor and indoor units for a system.

Hisense VRF Capacity Correction - Refrigerant Piping Length

Details how to correct cooling and heating capacities based on piping length.

Hisense VRF Troubleshooting

Hisense VRF Initial Troubleshooting Steps

Covers basic checks for power, wiring, switches, and displays for common issues.

Hisense VRF Detailed Troubleshooting Procedures

Provides structured procedures for resolving system malfunctions.

Hisense VRF Servicing

Hisense VRF Electrical Box Removal Procedure

Detailed steps for safely removing the entire electrical box.

Hisense VRF Compressor Removal Steps

Critical procedure for removing the compressor unit.

Hisense VRF Refrigerant Oil Replacement

Instructions for replacing refrigerant oil, including handling clogged circuits.

Hisense VRF Stop Valve Removal Procedure

Detailed steps for removing stop valves.

Hisense VRF Sensor and Switch Removal

Covers removal of high pressure switch, sensors, and thermistors.

Hisense VRF Main Parts

Hisense VRF Inverter Unit Details

Provides specifications, protective functions, and arrangements for the inverter unit.

Hisense VRF Pressure Sensor Controls

Explains high and low pressure control mechanisms and sensor characteristics.

Hisense VRF Optional Function

Hisense VRF Field Work Instruction

Hisense VRF Refrigerant Leakage Safety Precautions

Details critical safety measures regarding refrigerant concentration and ventilation.

Hisense VRF Test Run

Hisense VRF Test Run Using Remote Control

Step-by-step guide for performing a test run with the remote control.

Hisense VRF Outdoor Unit Side Test Run Procedure

Instructions for conducting a test run directly from the outdoor unit.

Summary

Hisense VRF Air Conditioner General Data

Hisense VRF Safety and Control Device Settings

Explains settings for compressor protection devices like high-pressure switches and oil heaters.

Hisense VRF Piping System

Hisense VRF Refrigerant Pipe Connection - 3 Pipe Heat Recovery

Details pipe sizes and connection methods for 3-pipe heat recovery systems.

Hisense VRF Refrigerant Pipe Connection - 2 Pipe Heat Pump

Details pipe sizes and connection methods for 2-pipe heat pump systems.

Hisense VRF Additional Refrigerant Charge Calculation

Explains how to calculate and charge additional refrigerant for the system.

Hisense VRF Capacities and Selection Data

Hisense VRF System Selection Procedure

Guides users through selecting the appropriate outdoor and indoor units for a system.

Hisense VRF Capacity Correction - Refrigerant Piping Length

Details how to correct cooling and heating capacities based on piping length.

Hisense VRF Troubleshooting

Hisense VRF Initial Troubleshooting Steps

Covers basic checks for power, wiring, switches, and displays for common issues.

Hisense VRF Detailed Troubleshooting Procedures

Provides structured procedures for resolving system malfunctions.

Hisense VRF Servicing

Hisense VRF Electrical Box Removal Procedure

Detailed steps for safely removing the entire electrical box.

Hisense VRF Compressor Removal Steps

Critical procedure for removing the compressor unit.

Hisense VRF Refrigerant Oil Replacement

Instructions for replacing refrigerant oil, including handling clogged circuits.

Hisense VRF Stop Valve Removal Procedure

Detailed steps for removing stop valves.

Hisense VRF Sensor and Switch Removal

Covers removal of high pressure switch, sensors, and thermistors.

Hisense VRF Main Parts

Hisense VRF Inverter Unit Details

Provides specifications, protective functions, and arrangements for the inverter unit.

Hisense VRF Pressure Sensor Controls

Explains high and low pressure control mechanisms and sensor characteristics.

Hisense VRF Optional Function

Hisense VRF Field Work Instruction

Hisense VRF Refrigerant Leakage Safety Precautions

Details critical safety measures regarding refrigerant concentration and ventilation.

Hisense VRF Test Run

Hisense VRF Test Run Using Remote Control

Step-by-step guide for performing a test run with the remote control.

Hisense VRF Outdoor Unit Side Test Run Procedure

Instructions for conducting a test run directly from the outdoor unit.

Hisense AVWT-192FFFH Specifications

General IconGeneral
BrandHisense
ModelAVWT-192FFFH
CategoryAir Conditioner
LanguageEnglish

Related product manuals