GX-Series Control Panel Installation and Setup Guide
6-72
Output Functions
Vib
Test
ATM1-4 Fault
Bell
Test
Comms
Test
Door
Prop
Door
Forced
Listen-In
Zone Function 71 72-75 76 77 78 79 80 81
01 Final
- - - - - ? - -
02 Exit
- - - - - ? - -
03 Intruder
- - - - - ? - ?
04 24 Hours
- - - - - ? - -
05 Security
- - - - - ? - -
06 Dual
- - - - - ? - -
07 Entry
- - - - - ? - -
08 Push Set
- - - - S? ? - -
09 Keyswitch
- - - - - ? - -
10 Secure Final
- - - - - ? - -
11 Part Final
- - - - - ? - -
12 Part Entry
- - - - - ? - -
13 PA
- - - - - ? - ?
14 PA Silent
- - - - - ? - ?
15 PA Delay
- - - - - ? - ?
16 PA Delay Silent
- - - - ? ? - ?
17 Link
?
- - - - ? ? -
18 Spare
? - - - - ? - -
19 Fire
- - - - - ? - ?
20 Tamper
- - - - - ? - -
21 Bell Tamper
- - - - - ? - -
22 Beam Pair
- - - - - ? - -
23 Battery Low
- A - - - ? - -
24 Line Fail
- A - - - ? - -
25 AC Fail
- A - - - ? - -
26 Log
- - - - - ? - -
27 Remote Access
- - - - - ? - -
28 Video
- - - - - ? - -
29 Video Exit
- - - - - ? - -
30 Intruder Delay
- - - - - ? - ?
31 Log Delay
- - - - - ? - -
32 Set Log
- - - - - ? - -
33 Custom-A
?
- - - ? ? ? -
34 Custom-B
?
- - - ? ? ? -
35 Exit Guard
L - - - -L ? L
-
36 Mask
- A - - - ? - -
37 Urgent
- - - - - ? - -
38 PA Unset
- - - - - ? - ?
39 Keyswitch Reset
- - - - - ? - -
40 Bell Fail
- A - - - ? - -
41 Intr Low
- - - - - ? - ?
42 Intr High
- - - - - ? - ?
43 PSU Fault
- A - - - ? - -
44-46 Not Used
- - - - - ? - -
47 Vibration
- - - - - ? A -
48 ATM-1
O - - - - ? - -
49 ATM-2
O - - - - ? - -
50 ATM-3
O - - - - ? - -
51 ATM-4
O - - - - ? - -
52 Alarm Extend
- - - - - ? - -
Key:
S = Activates when system is set (armed)
P = Activates when system is Part set (Part armed)
U = Unset (disarmed)
A = Activated in any condition
- = No effect
? = Activation dependant on system programming
X = Activates during Exit Time
E = Activates during Entry
L = Switches output off if linked to destination output
T = Activates if zone resistance is less than value for tamper s/c or greater than value for tamper o/c
O = Activates when zone is omitted (bypassed)
Table 6-21. Output Activations per Zone

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell GX-Series and is the answer not in the manual?

Honeywell GX-Series Specifications

General IconGeneral
BrandHoneywell
ModelGX-Series
CategoryControl Panel
LanguageEnglish

Related product manuals